Miniclima Datasheet (current Series EBC 10/11)
Recommended Volume of the Showcase
Not exceeding 3m³ (EBC 10)
Not exceeding 5m³ (EBC 11)
Dehumidification Capacity at Ambient Conditions of 22ºC, 50% RH
2.3 g/h (EBC 10)
3.8 g/h (EBC 11)
Humidification Capacity at Ambient Conditions of 22ºC, 50% RH
5.0 g/h
Sample Achievable Set Point Range at Ambient Conditions of 22ºC, 50% RH.
30 to 75%RH
Permissible Ambient Conditions for Operation and Storage
5 to 35ºC / 15 to 80% RH, non-condensing
Tolerance - typically achievable
Setpoint at 30%RH: ±2%RH (max: ±3%RH)
Setpoint at 75%RH: ±3%RH (max: ±5%RH)
Electrical Connection
90 to 264 VAC / 47 to 440 Hz
System Voltage (Internal)
12 VDC
Power Consumption
65 Watts (max)
Weight
6.6 kg (without accessories, bottle, flexible hoses, cables, etc..)
Noise Emission, free standing, measured from 1 m
48.1 dB(A)
Noise Emission, mounted in a showcase plinth, measured from 1 m
37 dB(A) - plinth: 20mm particleboard, with air slots and sound insulation
Housing Material
Coated steel sheet, 1.5 mm, Pigeon-blue (RAL 5014)
© Copyright 2009 Humidity Control Systems Ltd Tel: 0044 (1) 522 753722